| dc.description.abstract |
ABSTRACT : Retrieval-Augmented Generation (RAG) systems are increasingly proposed for clinical information retrieval, yet evaluations are overwhelmingly conducted on
cloud infrastructure in high-income settings, reported gains from advanced retrieval techniques are seldom subjected to ablation, and automated judges are
routinely drawn from the same model as the system under test. This article reports the third objective of a design science study: evaluation of the retrieval
performance, response latency and perceived usability of a developed On-Premises RAG system for health records retrieval in Level 5 hospitals in Kenya. Twelve curated queries spanning six classes, each paired with a ground-truth reference computed by structured query over a synthetic corpus of 1,603 indexed
chunks, were executed through the live pipeline under three configurations, being the full advanced pipeline, a naive vector-search baseline and a no-rerank
ablation, with retrieval depth held at eight chunks throughout. Two deterministic, judge-free measures were computed for all three configurations, and three
judged measures were computed for the naive configuration by Qwen2.5-7B-Instruct, a judge independent of the Phi-4 Mini Instruct (3.8B) generator in both
instance and model family and served locally, so that no health-record content left the machine. Contrary to expectation, the naive baseline outperformed both
advanced configurations on key-fact context precision, at 0.687 against 0.633 and 0.591 over the nine queries for which the measure is defined, and on key-fact accuracy, at 0.491 against 0.400 and 0.275 over all twelve. It was also the only configuration to meet the thirty-second design target, at a mean of 13.99 seconds against 34.33 seconds for the no-rerank ablation. Judged context recall of 0.533 over ten defined scores and faithfulness of 0.599 over eleven, the latter below the
criterion of 0.80 adopted by the study, together indicate that incomplete retrieval rather than unsupported generation was the binding constraint. Performance varied sharply by class: catalogue lookup recorded key-fact accuracy of 0.875 while aggregate counting recorded 0.167 and identifier-keyed per-patient retrieval
0.244, the last with judged context recall of 0.000. Thirteen intended users at the two study hospitals recorded completion of between 84.6 and 100.0 per cent of six task scenarios, rated source verifiability highest at a median of 5, and returned a mean System Usability Scale total of 80.6; every one of them identified per- patient retrieval as routine, which is the class on which the system performed worst. The study concludes that added pipeline complexity conferred no measured benefit at this corpus scale, and that aggregate and identifier-keyed questions require structured and exact-match retrieval alongside semantic search. |
en_US |